InoPurauto-2400 is a high-efficiency automatic nucleic acid extraction equipment based on the magnetic bead method to extract nucleic acid.
During the purification process, pipetting, lysis, washing, elution, and PCR system setup steps can be performed automatically at the workstation.
One-stop operation without manual intervention, can extract 24x10 mL samples simultaneously; This is more efficient and convenient than manual and semi-automatic extraction.
At the same time, standardized and automated operating steps prevent human error and experimental results are more reliable and reproducible.
Large volume extraction to meet special needs
> The maximum reaction system of the sample library is 10 mL and can meet the needs of cfDNA extraction.
> The elution hole elutes a small volume to meet nucleic acid concentration requirements.
High precision liquid processing
> Dual channel pipetting design, 1x50-5000uL fits 1mL/5mL pipettor and 1x1-200uL fits 200uL pipettor.
> Detailed pipetting parameter settings for different liquids can effectively improve accuracy.
Easy to learn operating software
> Graphical user interface, program editing can be completed without complex operations.
> Extensive built-in libraries of consumable carriers and fluids to reduce customer program matching time.
> Users can choose according to their needs to complete the entire process of liquid handling, extraction and PCR/qPCR setup.
Technical Specifications
Model | InoPurauto-2400 |
Function | Automatic pipette samples and reagents, extract nucleic acid and set-up PCR systems |
Information Management | Support external USB scanner, barcode scanning function, automatic scanning function |
Pipetting Principle | Air displacement pipetting technology |
Pipettor | One 5000 μL pipettor, one 200 μL pipettor |
Pipetting Range (μL) | 1-5000 μL |
Tips | Inovialab tips, and other tips compatible with this instrument |
Liquid Detection | Pressure detection: liquid level detection, tip clogging detection and residual liquid detection |
Samples Per Run | 1-24 |
Extraction Processing Volume | 50-10000 μL |
Extraction Uniformity | CV≤5 % |
Single Sample Consumable | Support |
Extraction Temperature Control | Elution, lysis temperature control : RT - 120°C |
UV Sterilization | Separate UV lamp: extraction area, pipetting area and waste container area |
Filter | Equipped with three Hepa Filters |
Instrument Port | USB Port |
Noise | ≤60 dB |
Power Supply | 220 V, 8 A, 50/60 Hz |
Net Weight | 130 Kg |